Saturday, March 14, 2009

Thermoelectric Temperature Controller - Part 2

Stage 3 - TEC and Heat Sink Selection

In my last posting I explained how to calculate the left hand side of the energy balance equation for a thermoelectric fermentation cooler. In this post, I will explain how to select a device to balance the energy equation and find that Q_pumped value. In addition, I will explain how to select the heat sinks that will be required to optimize its performance.

When searching for thermoelectric devices, you will usually come across the specification sheet that describes how much heat the device can pump under certain temperature conditions and at various power conditions. The performance curve for a CUI Inc peltier device is shown at left. Note, I use the terms peltier device and TEC interchangeably thorughout my blog, but these are essentially the same things. On the bottom of the plot, the y-axis shows the amount of heat that the device can pump at various currents as a function of the temperature across the device. Let's look a little closer at what these curves are telling us. Again focusing on the bottom section, select the curve for 3.9A, which represents running the device at 3.9 amps current. As you increase the temperature difference between the hot and cold sides of the TEC, the amount of heat that the device can pump is decreased. This is due to the fact that the device in creating this temperature differential between each side must expend some of it's available power maintaing it. When the device tries the maintain greater temperature differences, it reduces the amount of energy available to move heat through the device. So you must select what you want; do you want the device to be able to pump a lot of heat, or is it more critical that the cold side of the device be very cold? An example of the first might be trying to cool a CPU; you don't care if the CPU gets down to -10 deg C, you just want all that overclocked heat away from the processor. An example of the latter is cooling a laser for an optical application; you may not have a lot of heat there, but you really want the device to be cold for optimum laser performance. I could go on, but I digress, let's look at the rest of the plot.

The top part of the curve shows the voltage required to drive the device at a particular current. You basically want to first select the voltage that you will be using, which will be dependent on your power supply. Note that wall wort power supplies may be underpowered for TEC applcations; though they can provide the correct voltage, they can not provide enough current to drive it properly. Also, it is not feasible to use AC voltage supply as the cooler will not work at all - it must be DC.

One other item that should be discussed is that you will often find two curves; each curve describes the performance at a different hot side temperature. Both sets of curves may be similar, however, heat sink selection and ambient temperature conditions will determine which set of curves is most appropriate to use. For example, let's say you have a heat sink with a very limited amount of heat transfer capability attached the hot side. Heat will get "backed up" at the hot side which will cause the hot side to rise in temperature. Another example may be that you have a great heat sink on the hot side, but you are trying to reject heat to a very hot environment, say an semi-enclosed black box in a sunny location on a hot summer day where temperatures can easily reach 50-60 deg C. For my purposes, I chose to use the curve specified for T_h = 27 deg C as I knew that I would have a great heat sink on the hot side and would also be rejecting heat to a room temperature of roughly 20-25 deg C.

I chose first to make a prototype system that I could scale up later once I proved out my calculations and circuit. For this prototype, I wanted to just cool a can of soda so I selected the CP40336 by CUI Inc, which is a middle of the road TEC
, powerwise, that can pump heat at a maximum of 33.4 Watts. I wanted to run the circuitry of my control system and the TEC with 12 VDC since the device could possibly be used into a mobile setup using the outlet in my car. Now I have the voltage and a rough idea of the current I will require, roughly 3.0 amps. The next step is figuring out your temperature differential.

From my last post, you have the means to calculate the amount of heat you need pumped (the left hand side of the energy balance equation). Let's say I determined that the heat I need pumped all adds up to 10 W (this is not an accurate number, this is just an example). Looking at the plot, you trace over from 10 W (shown in blue in the figure) to the current line that your device will run at, which for me is ~3.12 amps, and trace down from there. This will give you the maximum temperature differential that you can run the device at to get the cooling you desire, in this case, ~44 deg C. If the temperature differential is less, you will get more cooling power. How do you get this temperature differential? This is where some heat sink calculations come into play.

The first thing you need to determine before you start looking at heat sinks are the ambient temperatures inside and outside of the cooler box. For my application, I wanted to be able to keep the inside temperature of the cooler box at a cool 4.5 deg C (~40 deg F). Also, I knew that the outside temperature would be roughly room temperature or 22 deg C (~72 deg F).

Another item that can't be overlooked is that the cold side of the device is the side that sees the heat pumped. The hot side, however, sees this amount of heat plus it must also remove the heat generated by the electricity running through it. This type of heating is called Joule heating and Q_j can simply be calculated by:


where v is the voltage and i is the current that you are supplying to the device. To help visualize dealing with the Q_j, let's look at the energy balance of the system another way which incorporates the power supplied to the TEC, as shown at left and put into equation form below.

This energy balance is different from the one that I posted in my first post because I didn't want to introduce too many concepts at once. This energy balance is technically the correct overall system balance equation.

So now you have the amount of heat that needs to pass through each side of the device and the corresponding temperatures. Since there are many different heat sinks out there, you have many options, but as a general rule is that you will want a heat sink with lower thermal resistance (deg C/W value) on the hot side than on the cold side since the hot side is required to reject more heat than the cool side must accept.

The equations for the cold side and hot side heat sinks are as follows:


where T_ac and T_ah [deg C] are the ambient temperatures inside and outside the cooler box, respectively, and R_c and R_h [deg C/W] are the thermal resistances of the cold and hot side heat sinks, respectively. Since you know the temperature differential across the TEC from the plot, it is helpful to combine these equations above into one as shown:

The next task is to find heat sinks and start plugging their values into the equation above and seeing if they will satisfy the following condition:

The heatsinks must be able to create a situation where you have at a maximum a device temperature differential that you found in the device plot. For example, previously I found that if I planned to pump 10 W at 12VDC, I would require a 44 deg C maximum temperature differential. Let's say then I select a hot side heat sink value of 0.1 C/W and a cold side heat sink value of 0.5 C/W. Calculating it out with the equation above, I would get a 30.6 deg C differential across the device, which would be adequate for my application and also give me a little wiggle room. However, if I chose a heat sink values that were both 0.5 C/W, I would get a 49 deg C across the device and I would never be able to cool the cooler box to the desired level. Note that for this example I selected values that are common to typical aluminum/copper heat sinks with fans (forced convection).

Going through a few iterations of heat sink calculations, you should be able to settle upon a heat sink combination that will work for your application. I created a little plot in excel that calculated the values that would meet my specifications as a reference as shown below. It is critical to observe that if you do not have heat sinks on the hot side of the device, you may initially get cooling on the cold side, but it will eventually heat up as the heat on the hot side needs some place to go. That heat then migrates back through the cooler to the cold side increasing it's temperature dramatically, turning the device into a heater instead.

With the information supplied in this and the previous post, you should now be able to select the hardware for a thermoelectric cooler and understand how they all work together. Though for my project I am initially building a small scale 12-fl oz prototype and then developing a larger 5-6 gallon fermentation refrigerator, these equations scale to any size. The only difference for larger scale systems is that you may need more than one TEC since there is a limit to the size of commercially available devices.

In the next post, I will talk about the control circuitry that will be required to control my small scale prototype device. This will include circuit component options and circuit schematics.







4 comments:

  1. Great post so far on the TEC lager fermenter. In some of my work with TE devices I've found that the greatest hurdle to implementing them is engineering your device so that the T_hot and T_cold surfaces stay sufficienty separate from one another. Simply because of the proximity of the hot and cold sides (thin wafer), TE devices are inherently thermally and space inefficient because they are so darn thin and even though each side has a different temperature, it is a bit tricky to eliminate interference between them even with heat sinks and clever insulation. It can be minimized but not completely avoided. Doesn't mean this isn't possible, thought! In my thought experiments , I have not figured out how many devices should be used and whether they should be in parallel or series, not to mention what kind of power supply and thermostat control. So, I'm curiously watching your blog. Thanks!

    ReplyDelete
  2. DHill -

    The insulation of the T_hot and T_cold sides can be a bit tricky. I've seen accomplished by using a heat spreader (usually aluminum) on one of the sides that has the same footprint as the TEC but is somewhat thick (~0.5"). The heat sink can then be attached to the heat spreader with insulation between the cold and hot heat sinks.

    Also, in regards to how many devices should be used, I'm finding that it may be 4+ TECs. I'm currently seeking a power source that can handle this as well - I'm looking to motor control circuits for the answer.

    ReplyDelete
  3. Hello,
    very interesting all of this !!
    Could you tell me whre you found this "heat spreader" ?
    Another thing : in your example, in your equation for delta T, is Tc equal to 4,5°C and Tah equal to 22°C ?
    PhiLippe

    ReplyDelete
  4. PhiLippe -

    The heat spreader mentioned is any very thermally conductive material, i.e. copper or aluminum work best. These materials can be found at McMaster-Carr or similar websites for cheaper prices, but they may have to be machined down. Remember get a good thermal interface between the heat spreader and the TEC or heat sink as possible, use thermal epoxy for this.

    As for the temperatures, Tac = 4.5 deg C and yes, Tah = 22 deg C. You can get Tc from the equation Tac - Tc = Rc * Qpumped.

    Hope this helps!

    ReplyDelete